Description
The surge transmitter (SDV-Exd pressure transmitter with RS485 interface) is used to measure absolute pressure or gauge pressure of air behind the compressor.
The surge transmitter makes it possible to determine compressor gas-dynamic stability losses by the value of relative pulsations of air pressure behind the compressor or by the rate of air pressure drop behind the compressor.
The surge transmitter is manufactured in Non-explosion-proof option (SDV) and in Explosion-proof versions (SDV-Exd).
Pressure transmitters are supplied with valve blocks.
Applications
-
Oil and gas industry
-
Power engineering
-
Chemical industry
-
Measuring equipment
-
Test stands
Characteristics
| Ambient Temperature, °C | −50 +105 |
| Dust and Moisture Protection Class | IP54 (for plug) |
| Electrical Connector | 2RMG24B19Sh1E2 |
| Exchange Rate, kbps | 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 115.2 |
| Group for Resistance to Ambient Temperature and Humidity (per GOST 52931) | С4 |
| Group for Resistance to Mechanical Impacts (per GOST 52931) | Р2 |
| Group for Resistance to Mechanical Impacts (per GOST R 52931) | G2 |
| Housing Materials | aluminum alloy |
| Indication and Configuration | for transmitters with digital signal – via interface |
| Mass, kg, Not Exceeding | 1,5 |
| Materials in Contact with Measured Medium | titanium alloy VT-9, stainless steel 12X18H10T, stainless steel 316L, Viton |
| Measured Medium Temperature, °C | −50 +105 |
| Nominal Power Supply Voltage, V | 24±0,5 |
| Operating Temperature Range, °C | −50 +105 |
| Power Supply Voltage Range, V | 21,0-30,0 |
| Process Connection | М14×1,0 |
| Temperature Error, % per 10 °C | ±0,15% |
| Error, % of Measurement Range | ±0,75 |
| Input Signal/Power Supply | RS-485 (MODBUS-RTU) |
| Warranty Period | 3 years |
| Absolute Pressure (AP) | 1.7 MPa |
| Gauge Pressure (GP) | 1.6–3.2 MPa |