Description
Specialized compact SDV “Kommunalets” intelligent pressure transmitters with a 4–20 mA unified current output signal are designed for use in commercial heat energy metering units.
The multi-range transmitter design of SDV “Kommunalets” reduces warehouse costs by minimizing stock of transmitters with different measurement ranges and shortens repair times.
Versions
General industrial version of gauge pressure transmitter with Upper Range Limit (URL) (2.5; 1.6; 1.0; 0.6 MPa), multi-range, factory-set to URL 1.6 MPa, with 4–20 mA current output signal, with digital electronics signal processing unit (ЭБ), climatic version UHL placement category 3.1, manufactured under AGVR.406239.001TU, available in the following options:
-
SDV-I-M 1.6 – M20×1.5
-
SDV-I-M 2.5 – M20×1.5
-
SDV-I-M 1.0 – G1/2
-
SDV-I-M 0.6 – G1/2
SDV intelligent transmitters are supplied with valve blocks.
Applications
-
Construction
-
Housing and utilities (HCS)
-
Measuring equipment
-
Test stands
How to Buy an SDV-I 1.6 Pressure Transmitter from AO NPK VIP
To purchase a general industrial SDV pressure transmitter or order manufacturing, obtain the final price, and calculate delivery, please send a request form to zakaz@npkvip.ru.
The price depends on the version and other parameters. For consultation on AO NPK VIP pressure measuring instruments, please call +7 (343) 302-03-53.
Characteristics
| Ambient Temperature, °C | −20 +80 |
| Dust and Moisture Protection Class | IP65 |
| Electrical Connector | DIN 43650A |
| Group for Resistance to Mechanical Impacts (per GOST R 52931) | G2 |
| Housing Materials | AISI 201 or 10X18H10T steel |
| Indication and Configuration | IK 4-20M for 4–20 mA signal transmitters |
| Mass, kg, Not Exceeding | 0,20 |
| Materials in Contact with Measured Medium | Titanium alloy VT-9, AISI 201 or 10X18H10T steel |
| Measured Medium Temperature, °C | −50 +125 |
| Nominal Power Supply Voltage, V | 24 |
| Overload Pressure | 3.0 × Gauge pressure |
| Power Supply Voltage Range, V | 12-36 |
| Process Connection | М20×1,5, G½ |
| Temperature Error, % per 10 °C | ±0,15 |
| Error, % of Measurement Range | ±0,5 |
| Input Signal/Power Supply | 4–20 mA |
| Calibration Interval | 5 years |
| Warranty Period | 3 years |
| Gauge Pressure (GP) | Upper Range Limits 0.6 MPa, 2.5 MPa |