Description
High-temperature compact SDV MVT intelligent pressure transmitters are designed for operation with high-temperature media in non-crystallizing liquids, steam, and steam-gas mixtures at temperatures up to +110 °C under gauge pressure and absolute pressure.
The accuracy, stability, and wide choice of output interfaces (4–20 mA, 0.4–5.5 V, RS485, CAN) of the SDV MVT transmitter allow building modern monitoring and automatic regulation systems.
SDV intelligent transmitters are supplied with valve blocks.
Applications
-
Power engineering
-
Water utilities
-
Food industry
-
Chemical industry
-
Oil and gas industry
-
Measuring equipment
-
Test stands
Materials used in SDV ensure reliable operation of the high-temperature transmitter with the following controlled (operating) media:
-
Distillate, fresh water, seawater (33 ± 3 g sodium chloride NaCl per 1 L distilled water), air with water vapor — at medium temperatures from +1 to +100 °C
-
Diesel fuel, fuel oil, water steam, air — at medium temperatures from +1 to +110 °C
-
Oil, kerosene, gasoline — at medium temperatures from –25 to +110 °C
How to Buy an SDV MVT Pressure Transmitter from AO NPK VIP
To order a transmitter for high-temperature media, get prices, and delivery terms, please send a request form to zakaz@npkvip.ru.
The price of the instrument depends on the version and other parameters. For consultation on AO NPK VIP pressure measuring instruments, please call +7 (343) 302-03-53.
Specifications
| Ambient Temperature, °C | −50 +100 |
| Dust and Moisture Protection Class | IP54;IP55 |
| Electrical Connector | DIN 43650; 2RM 18; cable entry |
| Explosion-Proof Design | intrinsically safe electrical circuit 0ExiaIICT5X, Mining version ROExiaIMaX |
| Group for Resistance to Mechanical Impacts (per GOST R 52931) | G2 |
| Housing Materials | stainless steel 12X18H10T |
| Indication and Configuration | IK 4-20M communicator for 4–20 mA transmitters; for digital transmitters – via interface |
| Mass, kg, Not Exceeding | 0,45 |
| Materials in Contact with Measured Medium | titanium alloy VT-9, stainless steel 12X18H10T, stainless steel 316L, Viton |
| Measured Medium Temperature, °C | −50 +110 |
| Nominal Power Supply Voltage, V | 24/15/12/3,6/12 |
| Power Supply Voltage Range, V | 12-36/12-24/8-30/3,0-3,9/8-30 |
| Process Connection | М20×1,5; G½ |
| Temperature Error, % per 10 °C | 0,25; 0,5 |
| Error, % of Measurement Range | ±0,25; ± 0,5; |
| Input Signal/Power Supply | 4-20мА, 0,4-4 В, RS485, CAN, 1WIRE |
| Calibration Interval | 5 years |
| Warranty Period | 3 years |
| Absolute Pressure (AP) | 0.6; 1; 6; 10; 60 MPa |
| Gauge Pressure (GP) | 6 MPa |